Loading...
 
Translate Register Log In Login with facebookLogin and Register

Vitamin D test using elelctrospun nanofibers (looks promising) – Dec 2018

Electrochemical immunosensor based on magnetite nanoparticles incorporated electrospun polyacrylonitrile nanofibers for Vitamin-D3 detection

Materials Science and Eng: C, Vol 93, 1 Dec 2018, Pages 145-156, https://doi.org/10.1016/j.msec.2018.07.036

VitaminDWiki

Perhaps this could provide instant vitamin D testing by a machine

Tests for Vitamin D contains the following overview/opinion

  • Fact: Many countries no longer pay for more than 1 or even any Vitamin D tests
      They feel that vitamin D testing is not needed except for a few conditions
  • Fact: Vitamin D tests are not very accurate/consistent: typically +- 5 nanograms
  • Opinion: Home blood spot tests have similar accuracy/repeatability as the lab tests
  • Fact: Low cost vitamin D tests are coming, but are not available in the US yet
       Low-cost test by Nanosys is available outside of the US
       both yes/no 35 ng and quantitative ($13 in quantity)
       update Low-cost Vitamin D testers (about 13 dollars in quantity) – Feb 2018 including cost of readout device
  • Fact: 3 major gene problems are not noticed by standard Vitamin D tests
       ~ 20% of Vit D tests show OK levels in blood when genes restrict VitD getting to cells
       Hint that Vit D not getting to cells: Vit D related diseases run in your family
  • Fact: A vitamin D test will rarely (<1 in 1000) indicate that you are getting too much
  • Opinion: If only getting a single test, wait till after supplementing with Vit D
       3 months after starting a maintenance dose or 4 weeks after a loading dose

PDF is available free at Sci-Hub  10.1016/j.msec.2018.07.036
Image

In the present study, magnetite nanoparticles (Fe3O4 NPs) incorporated polyacrylonitrile nanofibers (PANnFs) having diameter of 350–500 nm, were electrospun and directly collected onto indium tin oxide (ITO) coated glass substrate. X-ray diffraction pattern of Fe3O4-PANnFs confirmed the existence of Fe3O4 NPs within the PANnFs. Nafion was used to make Fe3O4-PANnFs more adhesive to the ITO surface. Partial hydrolyzation of Fe3O4-PANnFs/ITO electrode was done using NaOH solution for the partial conversion of nitrile group (C≡N) into carboxyl and amine groups that was confirmed by Fourier transform infrared spectroscopy study. The hydrolyzed Fe3O4-PANnFs/ITO electrode was used as an immobilization matrix for monoclonal antibody specific to Vitamin-D3 (Anti-VD) via 1-ethyl-3-(3-dimethylaminopropyl) carbodiimide and N-Hydroxysuccinimide chemistry. Bovine serum albumin (BSA) was used as a blocking agent to block the non-specific sites onto Anti-VD/Fe3O4-PANnFs/ITO electrode surface. Fabricated BSA/Anti-VD/Fe3O4-PANnFs/ITO immunoelectrode showed improved biosensing parameters for Vitamin-D3 detection such as sensitivity of 0.90 μA ng−1 mL cm−2, limit of detection of 0.12 ng mL−1and detection range of 10–100 ng mL−1. The association and dissociation constants were obtained as 74.62 ng mL−1, 4.6 ng mL−1, respectively.

Created by admin. Last Modification: Tuesday July 31, 2018 15:06:51 GMT-0000 by admin. (Version 5)

Attached files

ID Name Comment Uploaded Size Downloads
10255 Ferronano.jpg admin 31 Jul, 2018 14:54 22.49 Kb 28
See any problem with this page? Report it (FINALLY WORKS)